RS485 light-isolated repeater Manual

E485GP is compatible with Siemens repeater 6 ES7 972-0AA01-0XA0, is the high-speed isolated PROFIBUS repeaters designed for PROFIBUS bus, applicable to all RS485 network such as the PROFIBUS network, PPI network, MPI network, MODBUS network and Free Port communication network. It can realize the signal isolation and amplification. When the RS485 communication distance is over the corresponding baud rate’s allowing, or nodes on the network are more than the allowed number, you should use repeaters to amplify the signal. The products have characteristics such as extending communication distance, automatically switching the flow of signals and automatically adaptation of baud rate. All their industrial-grade devices are anti-static and anti-lightning, make them work stably in the poor industrial environment.

When the number of nodes witch connected to the bus is more than 32 or of the connective cable between buses exceeds the maximum length of cable(see table below), you need to use repeaters to amplify signal.

Note 1

Baud rate

The maximum cable length of bus(m)

9.6 to 187.5Kbps

1000

500Kbps

200

1.5Mbps

100

Technical details

isolated voltage: 1000 VDC (up to 3000 VDC, statement is required when ordering)

communication rate: 0 ~ 1.5 Mbps automatically adaptive

greatest distance: 2km (9.6 Kbps), 1500m(19.2 Kbps), 800m(187.5 Kbps), 200m(500 Kbps), 100m(1.5 Mbps)

Power: 24 VDC 1W DC power supply

protection of open-circuit, short-circuit and gap fault of bus

600 W built-in anti-lightning protection,15KV ESD (electrostatic) protection

integrated terminal and bias resistors, data sending and receiving indicator light

temperature: -40 ~ +85

Dimensions: 855525 (LWH), installation of standard rail

Weight: 100 g

Picture of working principle:

Products’ shape and definition of terminal signals:

Definition of the bus paragraph 1 and 2’s connection terminal signal

Bus paragraph 1 connection terminal(left)

Bus paragraph 2 connection terminal(right)

Signal-name

description

Signal-name

description

A1

Bus paragraph 1’s RS485 signal negative

A2

Bus paragraph 2’s RS485 signal negative

B1

Bus paragraph 1’s RS485 signal positive

B2

Bus paragraph 2’s RS485 signal positive

FG

Chassis groundconnect the shielding layer of cable

FG

Chassis groundconnect the shielding layer of cable

A1

Bus paragraph 1’s RS485 signal negative

A2

Bus paragraph 2’s RS485 signal negative

B1

Bus paragraph 1’s RS485 signal positive

B2

Bus paragraph 2’s RS485 signal positive

FG

Chassis groundconnect the shielding layer of cable

FG

Chassis groundconnect the shielding layer of cable

+24V

External connect the anode of 24V DC power supply

0V

External connect the cathode of 24V DC power supply

Definition of programming device PG/OP socket(DB9F socket)signal

Pin number

Signal-name

description

1

-----

----

2

M24V

24Vground

3

RXD/TXD

Data wire B(RS485 signal positive)

4

----

----

5

M5V

Data reference potential(5V ground)

6

P5V

5V power anode

7

P24V

24V power anode